Electrical cables for shipboard use
SH-PC-U - Unarmoured power & control shipboard cable - XLPE / SHF1 - 600/1000V
These SH-PC-U unarmoured power & control cables are siutable for shipboard use, they have a HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2 , IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.
SH-PC-A - Armoured power & control shipboard cable - XLPE / SHF1 - 600/1000V
These SH-PC-A armoured power & control cables are siutable for shipboard use, they have a HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2 , IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.
SH-PC-U-F - Unarmoured Fire resisting power & control shipboard cable - Mica tape/XLPE / SHF1 - 600/1000V
These SH-PC-U-F unarmoured power & control cables offer enhanced fire resistance and are siutable for shipboard use, they have a Mica Tape +HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2 , IEC-60331-21 , IEC60331-31 Fire Resistance , IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.
SH-PC-A-F - Armoured Fire resisting power & control shipboard cable - Mica tape/XLPE / SHF1 - 600/1000V
These SH-PC-A-F armoured power & control cables offer enhanced fire resistance and are siutable for shipboard use, they have a Mica Tape +HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2 , IEC-60331-21 , IEC60331-31 Fire Resistance , IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.
SH-CI-C-U - Control & Instrumentation , Collectively Screened Unarmoured shipboard cable 150/250V ( 300V)
These SH-CI-C-U unarmoured cables are designed for control and instrumentation applications on board ships and offer a HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.
SH-CI-C-A - Control & Instrumentation , Collectively Screened Armoured shipboard cable 150/250V ( 300V)
These SH-CI-C-A amoured cables are designed for control and instrumentation applications on board ships and offer a HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.
SH-CI-C-U-F - Control & Instrumentation , Collectively Screened Unarmoured Fire Resisting cable 150/250V ( 300V)
These SH-CI-C-U-F unamoured fire resisting cables are designed for control and instrumentation applications on board ships and offer a Mica Tape / HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. IEC 60331-21, IEC60331-31 Fire resistance. Cables have Rina , ABS , Llyods and Veritas approvals.
SH-CI-C-A-F - Control & Instrumentation , Collectively Screened Armoured Fire Resisting cable 150/250V ( 300V)
These SH-CI-C-A-F unamoured fire resisting cables are designed for control and instrumentation applications on board ships and offer a Mica Tape / HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. IEC 60331-21, IEC60331-31 Fire resistance. Cables have Rina , ABS , Llyods and Veritas approvals.
SH-CI-I-U - Control & Instrumentation , Individually Screened Unarmoured shipboard cable 150/250V ( 300V)
These SH-CI-I-U unarmoured cables are designed for control and instrumentation applications on board ships and offer a HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.
SH-CI-I-A - Control & Instrumentation , Individually Screened Armoured shipboard cable 150/250V ( 300V)
These SH-CI-I-A armoured cables are designed for control and instrumentation applications on board ships and offer a HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.
SH-CI-I-U-F - Control & Instrumentation , Individually Screened Unarmoured Fire Resisting cable 150/250V ( 300V)
These SH-CI-I-U-F unamoured fire resisting individually screened cables are designed for control and instrumentation applications on board ships and offer a Mica Tape / HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. IEC 60331-21, IEC60331-31 Fire resistance. Cables have Rina , ABS , Llyods and Veritas approvals.
SH-CI-I-A-F - Control & Instrumentation , Individually Screened Armoured Fire Resisting cable 150/250V ( 300V)
These SH-CI-I-U-F amoured fire resisting individually screened cables are designed for control and instrumentation applications on board ships and offer a Mica Tape / HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. IEC 60331-21, IEC60331-31 Fire resistance. Cables have Rina , ABS , Llyods and Veritas approvals.
SH-CI-IC-U - Control & Instrumentation , Individually & Collectively Screened Unarmoured shipboard cable 150/250V
These SH-CI-IC-U unarmoured individually & collectively screened cables are designed for control and instrumentation applications on board ships and offer a HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.
SH-CI-IC-A - Control & Instrumentation , Individually & Collectively Screened Armoured shipboard cable 150/250V
These SH-CI-IC-A armoured individually & collectively screened cables are designed for control and instrumentation applications on board ships and offer a HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.
SH-CI-IC-U-F -Control & Instrumentation Individually & Collectively Screened Unarmoured Fire Resisting cable 150/250V
These SH-CI-I-U-F unamoured fire resisting individually & collectively screened cables are designed for control and instrumentation applications on board ships and offer a Mica Tape / HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. IEC 60331-21, IEC60331-31 Fire resistance. Cables have Rina , ABS , Llyods and Veritas approvals.
SH-CI-IC-A-F -Control & Instrumentation Individually & Collectively Screened Armoured Fire Resisting cable 150/250V
These SH-CI-I-A-F amoured fire resisting individually & collectively screened cables are designed for control and instrumentation applications on board ships and offer a Mica Tape / HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. IEC 60331-21, IEC60331-31 Fire resistance. Cables have Rina , ABS , Llyods and Veritas approvals.
SH-CI-U-U -Control & Instrumentation Unscreened & Unarmoured shipboard cable 150/250V (300V)
These SH-CI-U-U unarmoured power & control cables are siutable for shipboard use, they have a HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2 , IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.
SH-CI-U-A -Control & Instrumentation Unscreened & Armoured shipboard cable 150/250V (300V)
These SH-CI-U-A armoured power & control cables are siutable for shipboard use, they have a HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2 , IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.
SH-CI-U-U-F -Control & Instrumentation Unscreened & Unarmoured Fire Resisting cable 150/250V (300V)
These SH-CI-U-U-F unamoured fire resisting cables are designed for control and instrumentation applications on board ships and offer a Mica Tape / HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. IEC 60331-21, IEC60331-31 Fire resistance. Cables have Rina , ABS , Llyods and Veritas approvals.
SH-CI-U-A-F -Control & Instrumentation Unscreened & Armoured Fire Resisting cable 150/250V (300V)
These SH-CI-U-A-F unamoured fire resisting cables are designed for control and instrumentation applications on board ships and offer a Mica Tape / HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. IEC 60331-21, IEC60331-31 Fire resistance. Cables have Rina , ABS , Llyods and Veritas approvals.
SH-ICC -Control / Comms & Instrumentation Screened & Unarmoured cable - 60V
These SH-ICC unarmoured communication & control cables are siutable for shipboard use, they have a HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2 , IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.
Drag Chain / High flex Shipboard Cables
SHIP Drive - Screened Drag chain motor supply cables for shipboard applications 600/1000V
This Ship Drive cable is design for drag chain / high flexing shipboard cable applications . It is Oil & sunlight resistant , has enhanced oil resistance according to IEC 6092-350 AnnexF & Low temp behaviour at -40 according to IEC60092-350 annex E ,in addition it conforms to IEC60322-1-2 not flame propagation and IEC 60754-1 Halogen content and has Llyods Register approval.
SHIP Drive BR- Screened Drag chain motor supply cables for shipboard applications 600/1000V
This Ship Drive BR cable is design for drag chain / high flexing shipboard cable applications . It is Oil & sunlight resistant , has enhanced oil resistance according to IEC 6092-350 AnnexF & Low temp behaviour at -40 according to IEC60092-350 annex E ,in addition it conforms to IEC60322-1-2 not flame propagation and IEC 60754-1 Halogen content and has Llyods Register approval.
SHIP Feedback- Screened Drag chain control cables for shipboard applications 300/500V & 600/1000V
This Ship Feedback cable is design for drag chain / high flexing shipboard cable applications . It is Oil & sunlight resistant , has enhanced oil resistance according to IEC 6092-350 AnnexF & Low temp behaviour at -40 according to IEC60092-350 annex E ,in addition it conforms to IEC60322-1-2 not flame propagation and IEC 60754-1 Halogen content and has Llyods Register approval.